LOLER Checklist — Passenger / Goods Lift — lolerflow.co.uk
⬇ Save as PDF (Print → Save as PDF)
Complete on site, then save:
Work through each item during the examination. Mark results and add observations, then click "Save as PDF" above.
6-month examination interval:
This equipment carries persons — LOLER 1998 Regulation 9(3)(a) requires a thorough examination at least every 6 months.
Free Passenger & Goods Lift LOLER Inspection Checklist
LOLER 1998 (SI 1998/2307) · Examination interval: 6 months (carries persons) · Working document only — not a substitute for the signed ROTE · Template by
lolerflow.co.uk
Lift Description
Serial No. / Asset Ref.
Date of Examination
Competent Person
1 · Car, Doors and Access
Item
Observations
Result
Car structure — floor, walls, ceiling, fixings, no deformation
P
F
N/A
Car door(s) — condition, operation, door closer, all safety edges
P
F
N/A
All landing doors — condition, interlocks tested (car not moving when door open)
P
F
N/A
Door interlocks — car cannot move with any landing door open; no door opens in motion
P
F
N/A
SWL / capacity plate — legible, posted in car
P
F
N/A
2 · Suspension and Safety Gear
Item
Observations
Result
Suspension ropes / chains — wear, broken wires, corrosion, equalisation
P
F
N/A
Guide rails — alignment, lubrication, bracket fixings
P
F
N/A
Safety gear — condition, date of last drop test, linkage to governor
P
F
N/A
Governor — rope, tension, overspeed trip setting confirmed
P
F
N/A
Buffers — pit buffers condition and security (spring or oil type noted)
P
F
N/A
3 · Machine Room and Controls
Item
Observations
Result
Machine room access — secure, ventilated, no water ingress
P
F
N/A
Drive unit (motor, gearbox, brake) — no overheating, no unusual noise
P
F
N/A
Final limit switches (upper and lower) — function confirmed
P
F
N/A
Emergency lighting and alarm bell — tested from car
P
F
N/A
Pit — safe access, pit stop switch, lighting, sump pump (where fitted)
P
F
N/A
Pass — No defects
Safe to continue in service
Category B — Repair by:
Category A — Withdrawn
Immediate danger — out of service
Competent Person — Name and Signature
Date Signed
Next Examination Due